There are a lot of stages in the water purification process and even though it  might appear like one would desire a physics degree to learn, this guide need to assist to simplify the whole process of water purification.

The 1st stage in water purification incorporates the water being transported to and getting unloaded at the facility. All incoming loads of water are tested for Chloride (NaCl) and percentage of solids prior to unloading is allowed. Once all tests are done, the water can then be separated for distribution within the plant. Not all fluids will be sent to the very same area. Fluids containing high solid levels are sent directly to the dewater process, while all other fluids are sent to the inlet pits for commingling.

The water is then moved into the mix tanks, which are made to let for the commingling and circulation, through means of pneumatic and/or propelled agitation, of all incoming fluids as wells as the natural separation of heavy solids (fallout) and oil (precipitation). The tanks are separated into a high-solids and low-solids system designed to control all incoming fluids at the techniques entrance.

The 3rd stage in the process incorporates going via a multi-stage tank battery system and de-watering. 1st, the fluids traverse through the tank battery system called the rifle barrel, that is a chambered storage vessel with an adjustable skimming plate designed to capture oil as it separates from the fluids. All oil captured is sent to the "crude oil sales" tank and remaining effluent fluids from the gun barrel are sent to the 2nd stage of storage, two large holding tanks which allow for enough system volume capacities. That second step is called de-watering, that is where all the heavy solids captured in the system transfer to, and introduced to heavy molecular weight polymers and co-polymers.

Any fluid leftover after stage three of the operation are sent to the solid separator units where a series of adjustments as well as injections are made and the remaining effluent fluids of the solids separation units are subjected to a number of good quality control tests before clearance to the next stage of the procedure is allowed. Any levels indicated above working standards will require instant re-processing.

The fifth and final step called micron and multi-media filtration incorporates all fluids from step 4 are sent through a series micron and multi-media filtration units in respective order given that the fluid passed all necessities.